EU alert · Safety Gate Serious risk Lighting chains
Lighting chain "LED-Háló karácsonyi ég" Ante — risk: electric shock, fire
Published in the Safety Gate weekly report: · Ref. 0682/12
Summary
null The product poses a risk of electric shock and fire because:· The cross-sectional area of the wires is not sufficient and the wires can consequently overheat.· The wire ends soldered to the rectifying unit terminals and the LEDs are not adequately protected against pulling and twisting. · The accessible wires have only basic insulation and if they come into contact with the sharp edges of the rectifying unit…
A Safety Gate alert means that national authorities found a serious or relevant risk and took measures. The same product may also be sold under other names or online.
Product
Lighting chain "LED-Háló karácsonyi ég" — Ante
- Brand
- Ante
- Name / model
- DCH (on packaging)
- Batch number(s)
- 5 999048 633712
- Category
- Lighting chains
- Lighting chain with 40 serial connected, non-replaceable LED lamps.
What is the risk?
- null The product poses a risk of electric shock and fire because:· The cross-sectional area of the wires is not sufficient and the wires can consequently overheat.· The wire ends soldered to the rectifying unit terminals and the LEDs are not adequately protected against pulling and twisting. · The accessible wires have only basic insulation and if they come into contact with the sharp edges of the rectifying unit live wires can become accessible. The product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60598.
Photos
Source: Safety Gate — European Commission
Data and images: Safety Gate, © European Union, licensed under CC BY 4.0. EU Safety Radar is an independent information service; the text above is an editorial presentation of the official data — the entry in the source system is authoritative.