EU alert · Safety Gate Serious risk Protective equipment
Particle filter mask Promedor 24 “Promedor 24 FFP2 NR PREMIUM” — risk: health risk / other
Published in the Safety Gate weekly report: · Ref. A12/00489/23
Summary
The particle/filter retention of the material is insufficient (measured values: as low as 70%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other recommended measures, it may not properly protect the user. The product does not comply with the Personal Protective Equipment Regulation nor with the European standard EN 149.
A Safety Gate alert means that national authorities found a serious or relevant risk and took measures. The same product may also be sold under other names or online.
Product
Particle filter mask — Promedor 24
- Brand
- Promedor 24
- Name / model
- Promedor 24 FFP2 NR PREMIUM · FFP2 NR PREMIUM
- Batch number(s)
- 200333
- Barcode
- 8592445246096
- Category
- Protective equipment
- White particle filter mask with ear loops and black printing on its side. Product also sold online.
What is the risk?
- The particle/filter retention of the material is insufficient (measured values: as low as 70%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other recommended measures, it may not properly protect the user. The product does not comply with the Personal Protective Equipment Regulation nor with the European standard EN 149.
Measures taken
- Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end users
- Date of entry into force: 03/02/2023
- Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Ban on the marketing of the product and any accompanying measures
- Date of entry into force: 03/02/2023
- Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Stop of sales
- Date of entry into force: 03/02/2023
- Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Destruction of the product
- Date of entry into force: 03/02/2023
- Type of economic operator taking notified measure(s): DistributorCategory of measure(s): Stop of sales
- Date of entry into force: 03/02/2023
- Type of economic operator taking notified measure(s): DistributorCategory of measure(s): Recall of the product from end users
- Date of entry into force: 03/02/2023
Photos
Source: Safety Gate — European Commission
Data and images: Safety Gate, © European Union, licensed under CC BY 4.0. EU Safety Radar is an independent information service; the text above is an editorial presentation of the official data — the entry in the source system is authoritative.