EU alert · Safety Gate Serious risk Construction products
Carbon monoxide detector FireAngel “Carbon Monoxide Alarm” — risk: asphyxiation
Published in the Safety Gate weekly report: · Ref. A12/1279/15
Summary
null The product is not sufficiently sensitive with respect to the detection of carbon monoxide.The product does not comply with the relevant European standard EN 50291-1.
A Safety Gate alert means that national authorities found a serious or relevant risk and took measures. The same product may also be sold under other names or online.
Product
Carbon monoxide detector — FireAngel
- Brand
- FireAngel
- Name / model
- Carbon Monoxide Alarm · CO-9D
- Batch number(s)
- Batch number 130805
- Category
- Construction products
- Carbon monoxide detector with an integrated non-replaceable battery.
What is the risk?
- null The product is not sufficiently sensitive with respect to the detection of carbon monoxide.The product does not comply with the relevant European standard EN 50291-1.
Measures taken
- Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Recall of the product from end users
- Date of entry into force: 17/07/2015
Photos
Source: Safety Gate — European Commission
Data and images: Safety Gate, © European Union, licensed under CC BY 4.0. EU Safety Radar is an independent information service; the text above is an editorial presentation of the official data — the entry in the source system is authoritative.