EU alert · Safety Gate Serious risk Electrical appliances and equipment
Camera set Levelone “Surveillance, 4-Channel CCTV Surveillance Kit” — risk: electric shock
Published in the Safety Gate weekly report: · Ref. SR/00868/25
Summary
The power supply cable is composed of a Class II plug (without a protective earth conductor) and a Class I connector. If the power supply cable is used with a Class I electric appliance, there is no continuation of the protective earth conductor. In the event of a fault, the fault current would not be able to flow via the protective earth conductor, leading to the risk of an electric shock. The product does not…
A Safety Gate alert means that national authorities found a serious or relevant risk and took measures. The same product may also be sold under other names or online.
Product
Camera set — Levelone
- Brand
- Levelone
- Name / model
- Surveillance, 4-Channel CCTV Surveillance Kit · DSK-4001
- Barcode
- 4015867227862
- Category
- Electrical appliances and equipment
- 4-channel CCTV surveillance kit, four cameras monitor that send data to a computer, laptop, tablet or smartphone. Meant for outdoor use. Power supply cable enclosed with the product. Power Cable P.V.C. 3G 0.5mm. Product sold online, in particular via Amazon (ASIN: B0BSFPQV4K).
What is the risk?
- The power supply cable is composed of a Class II plug (without a protective earth conductor) and a Class I connector. If the power supply cable is used with a Class I electric appliance, there is no continuation of the protective earth conductor. In the event of a fault, the fault current would not be able to flow via the protective earth conductor, leading to the risk of an electric shock. The product does not comply with the requirements of the Low Voltage Directive nor with the European standard EN 60335-1.
Measures taken
- Type of economic operator taking notified measure(s): ImporterCategory of measure(s): Replacement of the power cable in the goods in stock.
- Date of entry into force: 02/01/2025
- Type of economic operator taking notified measure(s): DistributorCategory of measure(s): Recall of the power cable from end users
- Date of entry into force: 02/01/2025