OPSS Serious Hand tools
Product Safety Report: Telescopic Ladder sold via Amazon (2608-0058)
Published by Office for Product Safety and Standards (OPSS):
Reason for the recall
- The product presents a serious risk of injuries as the ladder could not hold the claimed weight without collapsing.
Reasonsee the original notice
Brandnot stated
Batch number(s)not stated
Barcodenot stated
Product
Telescopic Ladder sold via Amazon
- Category
- Hand tools
- Country of origin
- China
- Type of recall
- Product safety report
- Summary
- Product: Telescopic Ladder sold via Amazon
- Hazard: The product presents a serious risk of injuries as the ladder could not hold the claimed weight without collapsing.
- Corrective action: The import has been rejected at the border and destroyed.
- The listing has been removed by the online marketplace (Amazon).
- Product information
- Type
- Hand tools/accessories - Ladders (Non-Powered)
- Product carton identifiers
- X585 EFT26041128/180, FG0004160919E, SCY-DJ-1.9-A-GT-C
- Reference number
- SCGT-U K222, P2026042500001006E
- ASIN
- B0H5BS6LGX
- Importer
- Yongchangshi Shenchengying Gongmao Youxiangongsi
- Country of Origin
- China
- Product Description
- A telescopic extending ladder.
- Product Report and Image
- Link to product image and PDF
- Hazard
- The product presents a serious risk of injuries as the ladder could not hold the claimed weight without collapsing. If the ladder were to collapse while in use, the user could fall and receive serious injuries. The dimensions of the ladder were noncompliant, and the ladder allowed different distances between rungs while in use. There is also no protection in place to prevent squeezing when the ladder is being collapsed. The product also requires improvements to marking and labelling. Improvements are also required to the product’s required information and instructions.
- The product does not meet the requirements of the General Product Safety Regulations 2005.
- Corrective action
- The import has been rejected at the border and destroyed.
- The listing has been removed by the online marketplace (Amazon).
- Additional information
- PSD notification number: 2608-0058
- Notified by: Local Authority Trading Standards
What to do
- The import has been rejected at the border and destroyed.
- The listing has been removed by the online marketplace (Amazon).
- Product information
- Type
- Hand tools/accessories - Ladders (Non-Powered)
- Product carton identifiers
- X585 EFT26041128/180, FG0004160919E, SCY-DJ-1.9-A-GT-C
- Reference number
- SCGT-U K222, P2026042500001006E
- ASIN
- B0H5BS6LGX
- Importer
- Yongchangshi Shenchengying Gongmao Youxiangongsi
Source: Product Safety Alerts, Reports and Recalls (OPSS) — Office for Product Safety and Standards (OPSS)
Source: Office for Product Safety and Standards, GOV.UK. Contains public sector information licensed under the Open Government Licence v3.0. EU Safety Radar is an independent information service; the text above presents the official data in the original language — the notice published by the authority is authoritative.