OPSS Serious Adaptors plugs sockets
Product Safety Report: Intelligent Charger Power Supply For Karcher Fc3 Fc3d, Uk sold via Fruugo (2212-0085)
Published by Office for Product Safety and Standards (OPSS): · Ref. 2212-0085
Reason for the recall
- The product presents a serious risk of electric shock due to inadequate clearance of required withstanding voltage and creepage distances.
Reasonsee the original notice
Brandnot stated
Batch number(s)not stated
Barcodenot stated
Product
Intelligent Charger Power Supply For Karcher Fc3 Fc3d, Uk sold via Fruugo
- Name / model
- Number
- Category
- Adaptors plugs sockets
- Country of origin
- Unknown
- Type of recall
- Product safety report
- Summary
- Product: Intelligent Charger Power Supply For Karcher Fc3 Fc3d, Uk sold via Fruugo
- Hazard: The product presents a serious risk of electric shock due to inadequate clearance of required withstanding voltage and creepage distances.
- Corrective action: The listing has been removed by the online marketplace. We recommend owners stop using this product immediately. Contact the distributor you purchased from to request redress.
- Product information
- Type
- Electrical appliances and equipment - Replacement charger
- Model Number
- MX-0951000
- Country of Origin
- Unknown
- Product description
- A black replacement charger with a rounded rectangular shaped plug face in clear plastic packaging.
- Product Report and Image
- Link to product image and PDF
- Hazard
- The product presents a serious risk of electric shock due to inadequate clearance of required withstanding voltage and creepage distances. Under testing the product failed drop and impact tests. No instructions were provided with the product to ensure safe use. The CE marking measured only 2.71mm, below the minimum requirement of 5mm. Some of the required addresses, names and markings were not present.
- The product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.
- Corrective action
- The listing has been removed by the online marketplace (Fruugo).
- We recommend owners stop using this product immediately. Contact the distributor you purchased from to request redress.
- Additional information
- PSD case number: 2212-0085
- Notified by: Office for Product Safety and Standards
What to do
- The listing has been removed by the online marketplace. We recommend owners stop using this product immediately. Contact the distributor you purchased from to request redress.
- Product information
- Type
- Electrical appliances and equipment - Replacement charger
Source: Product Safety Alerts, Reports and Recalls (OPSS) — Office for Product Safety and Standards (OPSS)
Source: Office for Product Safety and Standards, GOV.UK. Contains public sector information licensed under the Open Government Licence v3.0. EU Safety Radar is an independent information service; the text above presents the official data in the original language — the notice published by the authority is authoritative.
Open the original notice (www.gov.uk) ↗ Official document (PDF) ↗